工程计算器
Cockcroft-Walton Multiplier Calculator
如何读懂图表。 C1, C3 and C5 are the pump capacitors on the AC side; C2, C4 and C6 are the smoothing capacitors; D1 to D6 are the rectifier chain that hands charge from one stage to the next. The DC output is taken across the smoothing column, so three stages give 2 × 3 × Vpk at no load, and n stages give 2 × n × Vpk.
A Cockcroft-Walton multiplier adds the AC peak once per stage, so n stages reach 2 × n × Vpk with nothing connected to the output. As soon as the load draws current, the stage capacitors partly discharge between cycles: the output sags by a voltage drop that grows with the cube of the stage count, and it carries a peak-to-peak ripple. This calculator returns the no-load output, that drop, the ripple, the loaded output and the effective output capacitance, so you can see whether the stage count and capacitance you picked still hold at the current you need.
输入
功能验证
Model: full-wave cascade, C = capacitance of one capacitor per stage, f = AC frequency in Hz, I = DC load current.
- No-load output
- -
- 电压下降
- -
- Ripple (p-p)
- -
- Output under load
- -
- Effective output C
- -
其计算公式
No-load V0 = 2 × n × Vpk. Drop ΔV = (I / (f × C)) × (2n³/3 + n²/2 − n/6). Ripple δV = (I / (f × C)) × n(n+1)/2. Output under load = V0 − ΔV. Example: 6 stages, 10 kV peak, 1 nF per stage, 50 kHz and 1 mA gives 120 kV no-load, 3.22 kV drop and 116.8 kV loaded.
计算器不包含的内容
- Diode drops. Each stage loses forward voltage; with 6 stages that is 12 V, negligible at 100 kV and significant at 2 kV.
- Stray capacitance. Capacitance to ground and to the tank adds ripple the formula does not include.
- Frequency limit. Above roughly 100 kHz diode recovery and loop inductance dominate, and the formula overstates the output.
选择零件
Multiplier capacitors are Class 1 N4700 so the stages divide evenly: 径向圆盘 for compact stages, 螺钉端子 above 40 kV. Diodes are on the rectifier page.
请发送计算值和税率: 索取技术报价6小时内回复。